Send Email
Send SMS
Search
Superb Technologies


Mass Transfer Lab Equipment

Prominent & Leading Manufacturer from Ambala, we offer fluidized bed dryer apparatus, natural draft tray dryer, steam distillation set up, test load frame 5000kgf motorized 10 speeds, experimental water cooling tower and mass transfer lab equipment.

Fluidized Bed Dryer Apparatus

REQUEST CALLBACK

Fluidized Bed Dryer Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 38,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
Length500 mm
Power3 kW
PhaseSingle Phase
Diameter80 mm
Voltage220V AC

This is a dryer in which moisture removal takes place by fluidization of solids particles by hot air. The set-up fitted with a specially designed, vertical glass column. The lower portion of the column is filled with fluidizing material. The material is supported on the screen mesh held between two flanges. Air from a compressor is heated in the heater box and passed through the column. Flow control and by-pass valve are fitted to regulate the airflow. At the top outlet of column a cyclone is provided tocollect any solid particles taken out by the air stream.

Experimentation:

  • To study the fluidized bed drying
  • To plot the drying curve under fluidized bed condition

Utilities Required:
  • Granular and free flowing solid of size 1 to 2 mm

Technical Details:

  • Column: material borosilicate glass.
  • Cyclone separator: material stainless steel, compatible capacity with collector.
  • Air circulation: by forced draft fan, arrangement is done to vary the air flow rate.
  • Heating chamber: compatible capacity.
  • Heater: nichrome wire heater.
  • Temperature sensors: rtd pt-100 type.

Control Panel Comprises Of:

  • Digital temp controller: 0 1999°c (for hot air)
  • Standard make on/off switch, mains indicator etc


Additional Information:

  • Item Code: SMT-19
Yes! I am interested

Natural Draft Tray Dryer

REQUEST CALLBACK

Natural Draft Tray Dryer
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 22,000 / PieceGet Latest Price

Product Details:
Voltage220V AC
Power SourceElectric
PhaseSingle Phase
Power3 kW
Frequency50/60 Hz

Natural draft tray dryer is a dryer in which moisture removal takes place by heat under natural condition. The set-up consists of an insulated stainless steel chamber fitted with heater. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on the bottom, outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Temperature controller fitted in the set-up maintains the required temperature in the chamber.

Experimentation:

  • To Study The Drying Characteristics Of A Solid Material Under Batch Drying Condition
  • Determination Of Drying Rate And To Plot Moisture Lost With Time Under For Different Operating Conditions
Yes! I am interested

Steam Distillation Set Up

REQUEST CALLBACK

Steam Distillation Set Up
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 55,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
PhaseSingle Phase
Power2.5 kW
Voltage220 V AC
Floor Area0.75 x 2 m

The equipment consists of jacketed pressure vessel for distillation. Steam from a steam generator can either be allowed to enter in the outer jacket or in the vessel. The vapours form the top of the vessel are condensed in the shell and tube type condenser by circulating cooling water, supplied by laboratory overhead tank. The condensate is colleted in a separating chamber. The set-up is fitted with steam trap, control valves, pressure gauge, temperature sensors and other instrumentations required.

Experimentation:

  • To study the characteristics of Steam Distillation.
  • Efficiency of simple steam distillation set-up
Yes! I am interested

TEST Load Frame 5000kgf Motorized 10 Speeds

REQUEST CALLBACK

TEST Load Frame 5000kgf Motorized 10 Speeds
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 45,000 / PieceGet Latest Price

Product Details:
Surface FinishColor Coated
Power SourceElectric
Frequency50 Hz
Automation GradeAutomatic
Diameter198 mm
WeightApprox 20 Kg
MaterialIron
Voltage220 V

It consists of a cabinet which houses the electrical motor, reduction gear and the turret gear box. The loading is done by the upward movement of the lower platen of approx. 198mm dia. which is firmly fixed to the lead screw. When the lever is set in the neutral position, it isolates the lead screw from the rest of the drive mechanism and the lead screw can be manually moved up or down by operating the handle. The various rates of strain that can be obtained are as follows.

Other Details:

Position of Strain
Setting Lever

Position of Turret Setting Lever

1

2

3

4

5

.05
.025

.02
.01

.01
.005

.005
.0025

.002 in/min.
.001 in/min.

A
B


On the unit are fixed mains switch , a jewel lamp and a forward reverse switch. A relay is fitted inside the cabinet so that in case of a power failure the unit will not restart on its own on resumption of power, unless the switches are operated. The adjustable cross head can be set at any required height over the two pillars and secured in position by tightening the nuts. It carries a hexagonal proving ring adaptor. A bracket for strain dial gauge (dial) gauge to be ordered extra) is attached to one of the pillars of the load frame. The base with the two pillars and adjustable cross head is detachable and the whole upper portion above the level of the top plate of the cabinet can be fixed in its proper positon with the help of the clamping screws.

Yes! I am interested

Experimental Water Cooling Tower

REQUEST CALLBACK

Experimental Water Cooling Tower
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 45,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
PhaseSingle Phase
Power2.5 kW
Frequency50 Hz
Voltage250 V

The apparatus consists of a forced draught, counter flow type cooling tower. Cooling air is supplied by a blower. Air enters the tower at the bottom. Hot water is obtained from a water heater. Hot water is sprayed over the mesh packing through the nozzles and it flows down wards. Evaporative cooling of water occurs due to the current of air and water gets cooled. The student can study the operation of cooling tower and calculate the energy balance.

Yes! I am interested

Mass Transfer Lab Equipment

REQUEST CALLBACK

Mass Transfer Lab Equipment
  • Mass Transfer Lab Equipment
  • Mass Transfer Lab Equipment
  • Mass Transfer Lab Equipment
  • +1 Mass Transfer Lab Equipment
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 20,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Body MaterialStainless Steel
Power2.5 kW
Power SourceElectric
Voltage240 V
Frequency50 Hz

We hold expertise in offering premium quality Mass Transfer Lab Equipment to our valuable customers. Available with us at reasonable market prices, the apparatus is commonly used to study the process of mass transfer in various reactors. As per the requirements of our customers, this apparatus can be custom designed.

S.NOItem Distillation
SMT-01Liquid Liquid Extraction In Packed TowerSMT-06Bubble Cap Distillation Column
SMT-02York Schreiber Extraction UnitSMT-07Sieve Plate Distillation
SMT-03Spray TowerSMT-08Packed Bed Distillation Column
SMT-04Solid Liquid ExtractionSMT-09Steam Distillation Set Up

Absorption & DiffusionSMT-19Simple Batch Distillation
SMT-11Absorption In Sieve Plate Column

SMT-12Absorption In Packed Bed

SMT-13Absorption In Wetted Wall Column

SMT-14Vapor In Air Diffusion

SMT-15Solid In Air Diffusion Apparatus

Yes! I am interested

Forced Draft Tray Dryer

REQUEST CALLBACK

Forced Draft Tray Dryer
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 35,000 / PieceGet Latest Price

Product Details:
Floor Area0.75 x 2 m
Power2.5 kW
Power SourceElectric
Voltage220 V AC
PhaseSingle Phase

This is a dryer in which moisture removal takes place by means of forced draft action created by hot air. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to a electronic weighing balance, which is fitted on the bottom, outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from a blower passes through a heating chamber and is used as drying agent. Arrangement is done to vary the airflow rate.

Experimentation:

  • To study the drying characteristics of a solid under forced draft condition and determine the critical
  • moisture content.
  • To correlate the constant drying rate with air mass velocity.


Utilities Required:

  • Wet Solid.

Yes! I am interested

Absorption In Packed Bed Apparatus

REQUEST CALLBACK

Absorption In Packed Bed Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 35,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Compressed Air2 Bar, 4 cfm
Power SourceElectric
Voltage240 V
BrandSuperb Technologies
Frequency50 Hz

The set up consists of a glass column packed with Rasching rings. Liquid is fedat the top of the column through distributor. The solute gas and air are measured separately, mixed in a mixing chamber and then passed through the packed column vertically upward and absorbed in liquid. All the flow rates can be independently varied to simulate different conditions. Liquid sample can be taken out from the sampling point at the bottom of the column for analysis.

Experimentation:

  • To determine the number of transfer units, Height of transfer unit and overall mass transfer co-efficient for the given system.


Utilities Required:

  • Water Supply
  • Floor Drain.
  • CO2 cylinder with control valve, pressure regulator and Pressure gauges
  • Required Chemicals & Laboratory Glassware.


Additional Information:

  • Item Code: SMT-12
Yes! I am interested

Liquid- Liquid Extraction In Packed Tower

REQUEST CALLBACK

Liquid- Liquid Extraction In Packed Tower
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 35,000 / PieceGet Latest Price

Product Details:
Compressed Air2 Bar, 0.5 cfm
Power SourceElectric
Power3.5 kW
PhaseSingle Phase
Voltage220 V

The set-up consists of a glass column packed with Rasching rings. Continuous counter current contacts between the solvent and solute phases are made, which results into extract and raffinate streams. Flow meters (Rotameters) are used to note the flow of solvent & solute respectively. The continuous and dispersed phase streams are metered and derived from separate containers. The total set-up is housed in a well-designed rigid structure. The structure also supports tanks, piping, Rotameters, panel and other units.

Experimentation:

  • To determine overall mass transfer co-efficient based on continuous & dispersed phase.
  • To determine individual “Height of Transfer Unit” based on continuous & dispersed phase.


Utilities Required:

  • Water Supply
  • Drain.
  • Required Chemicals & Laboratory Glassware



Additional Information:

  • Item Code: SMT-01
Yes! I am interested

Packed Bed Distillation Column

REQUEST CALLBACK

Packed Bed Distillation Column
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 55,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Water Supply2 LPM at 5 m head
Power SourceElectric
PhaseSingle Phase
Voltage220V AC
Power6.5 kW

The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated reboiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapours form the top of column are condensed in the shell and tube type condenser by circulating cooling water, supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is provided for pressure & temp. measurement wherever necessary.

Experimentation:

  • To estimate the batch distillation curves for a binary system and verify the binary batch distillation equation for a known packed height.
  • To operate the column under total reflux condition and estimate the HETP for the packing.


Utilities Required:

  • Required Chemicals.
  • Refractometer for analysis



Additional Information:

  • Item Code: SMT-08
Yes! I am interested

Solid In Air Diffusion Apparatus

REQUEST CALLBACK

Solid In Air Diffusion Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 32,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
Voltage320 V
BrandSuperb Technologies
Frequency50 Hz
PhaseSingle Phase

Confirming a packed bed of spherical balls of a solid in a vertical tube, and observing its rate of diffusion into stream of air passed across the top of the tube can conveniently study the diffusion of solid into air. The equipment is fitted with a vertical glass column with a mesh near the base of column to hold the spherical balls. Spherical balls of known weight and diameter are filled in the column to make a packed bed. Air is allowed to pass through the silica gel chamber. From the bottom of the column, dry air is allowed to enter in the packed bed.

Experimentation:

  • To calculate the mass transfer co-efficient of vaporization of naphthalene in air using a packed bed of spherical particles of naphthalene.
  • To plot Sh/Sc 1/3 Vs Re on log 45g graph and determine the functional relationship.


Utilities Required:

  • Compressed Air Supply at 2 Bar, 4 CFM.
  • Weighing Balance 0.01 gm resolution.
  • Solid Spherical Balls of Naphthalene
  • Table for setup support.


Technical Detail:

  • Diffusion Column: Material Borosilicate Glass
  • Air flow Measurement: By Rotameter.
  • Instruction Manual: An ENGLISH instruction manual will be provided along with the Apparatus
  • The whole set-up is mounted on a powder coated base plate


Additional Information:

  • Item Code: SMT-15
Yes! I am interested

Vapour In Air Diffusion Apparatus

REQUEST CALLBACK

Vapour In Air Diffusion Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 32,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
PhaseSingle Phase
Voltage220V AC
Power0.6 kW
Frequency50 Hz

Using a small sample of the liquid in a narrow vertical tube, and observing its rate of evaporation into stream of air passed across the top of the tube can conveniently be used to study the diffusion of vapour of a volatile liquid into air. The set up consists of a glass tube placed in a water bath. A horizontal glass tube is fixed to the upper end of the tube and air is drawn through this by a small air pump included within the unit. Air flows over thistube maintaining partial pressure difference. A Traveling microscope with sliding vernier scale is provided to measure the rate of fall of solvent within capillary. A stirrer is fitted to maintain constant temperature inside the bath.

Experimentation:

  • Determination of the diffusion co-efficient of an organic vapour in air.
  • To study the effect of temperature on diffusion co-efficient.


Utilities Required
:

  • Required Chemicals & Laboratory Glassware.
  • Table for setup support.

Yes! I am interested

Rotary Dryer

REQUEST CALLBACK

Rotary Dryer
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 52,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Power SourceElectric
Floor Space1.5 x 2 m
PhaseSingle Phase
Voltage220V AC
Power4 kW

Rotary dryer is a unit in which drying is done by forced draft action created by hot air. The set-up consists of a long revolving cylindrical shell slightly inclined towards the outlet. The shell is fitted with two brackets for support. Air from a blower passes through a heating chamber serves the purpose of drying agent. An arrangement for rotating the dryer shell at low RPM is provided by means of an electrical motor and a reduction gearbox.Wet feed enters from one end of the cylinder and dry material discharges from the other end. As the shell rotates internal flights lift the solids and shower them down through the interior of the shell. This action increases the contact of wet solid against hot air making the dryer very effective. The flow of hot air is counter-current to solids. Flow control and by-pass valve are fitted to regulate the airflow.

Experimentation:

  • To study the operation of a Rotary Dryer.
  • To study the drying characteristics of a solid material under batch drying condition in a rotary dryer.


Utilities Required:

  • Wet Solid.


Additional Information:

  • Item Code: SMT-18
Yes! I am interested

Absorption In Sieve Plate Column Apparatus

REQUEST CALLBACK

Absorption In Sieve Plate Column Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 58,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Compressed Air2 Bar, 4 cfm
Voltage230 V
PhaseSingle Phase
Power SourceElectric
Frequency50 Hz

The set up consists of a column fitted with perforated plates. Liquid is fed at the top of the column through distributor. The solute gas and air are measured separately, mixed in a mixing chamber and then passed through the perforated plates vertically upward and absorbed in liquid. All the flow rates can be independently varied to simulate different conditions. Liquid Sample can be taken out from the bottom of the column for analysis.

Experimentation:

  • To study absorption of CO2 in aqueous NaOH solution in a sieve plate column.
  • To determine the gas phase mass transfer co-efficient, KG a


Utilities Required:

  • Water Supply
  • Floor Drain.
  • CO2 cylinder with control valve, pressure regulator and Pressure gauges
  • Required Chemicals & Laboratory Glassware.



Additional Information:

  • Item Code: SMT-11
Yes! I am interested

Spray Tower Apparatus

REQUEST CALLBACK

Spray Tower Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 45,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Compressed Air2 Bar, 0.5 cfm
Power SourceElectric
Voltage220 V
Power2.5 kW
Frequency50 Hz

The experimental set-up of Spray Tower consists of a glass column provided with necessary accessories. It operates on a semi-batch mode. Fine spray nozzle is fitted at the top. Feeds are metered by Rotameters and derived from separate feed tanks. The liquid-liquid interface can be maintained by controlling the flow rate of extract with the help of needle valve provided on Rotameter. Total set-up is housed in a rigid structure. The structure also supports tanks, piping, Rotameters and other unit.

Experimentation:

  • To study the effect of the dispersed phase flow rate on overall volumetric mass transfer coefficient.
  • Dispersed phase hold-up study.


Utilities Required:

  • Drain.
  • Required Chemicals & Laboratory Glassware.


Additional Information:

  • Item Code: SMT-03
Yes! I am interested

Solid Liquid Extraction Apparatus

REQUEST CALLBACK

Solid Liquid Extraction Apparatus
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 38,000 / PieceGet Latest Price

Product Details:
Power SourceElectric
PhaseSingle Phase
Power1.5 kW
Frequency50 Hz
Voltage220 V AC

This setup is designed to study the performance characteristics of solvent extraction of a particular component from a packed bed of solid material. The apparatus allows study of such systems as water/inorganic salts, water/sugar bed, methylene chloride/vegetable oil etc. The glass column is fitted with SS mesh to support the solid material. The solvent is introduced near the bottom of the column and it flows upward counter-currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. Solvent feed tank is kept in a bath fitted with heater and digital temperature controller is used to maintain the constant temperature.

Experimentation:

  • To study the effect of various system parameters like, solvent temperature, solvent rate and particle size on the %age recovery of oil from solid.


Utilities Required
:

  • Solid:10kg
  • Solvent: 30ltrs
  • Table for setup support


Additional Information:

  • Item Code: SMT-04
Yes! I am interested

Sieve Plate Distillation Column

REQUEST CALLBACK

Sieve Plate Distillation Column
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 58,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Wter Supply2 LPM at 5 m head
Power SourceElectric
PhaseSingle Phase
Voltage220V AC
Power6 kW

The column is made of Stainless Steel material with seven sieve trays. An electrically heated reboiler is installed at the bottom of the column.The bottom product is collected in the tank. The vapours form the top of column are condensed in the shell and tube type condenser by cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is provided for pressure & temp. measurement wherever necessary.

Experimentation:

  • To estimate the batch curves for a binary system and verify the binary distillation equation for a known number of theoretical plates.
  • To operate the column under total reflux condition and estimate the minimum number of theoretical plates required.


Utilities Required
:

  • Drain
  • Required Chemicals.
  • Refractrometer for analysis.


Additional Information:

  • Item Code: SMT-07
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Superb Technologies
Abhishek Aggarwal (Managing Director)
No. 80, HSIIDC Industrial Area , Ambala Cantt,
Ambala - 133001, Haryana, India
Call Us: 
Call Response Rate: 75%
Share Us :
F G T L



Home  |   About Us   |  Our Products  |  Site Map  |   Contact Us   |   Mobile Site

© Superb Technologies. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Superb Technologies